RT362
The RT362 Transmitter is a two-channel wireless temperature measurement system designed to monitor temperature on heated godet roll shells. The system features Dienes-compatible output signals for temperature control on Trützschler (SwissTex / Rieter) machines. Error detection modes protect the heater from damage and expedite troubleshooting in the event of a sensor or other failure. Digital circuitry from sensor input to signal output and generous clearance between the rotating and stationary components make the RT362 a robust and reliable element in the temperature feedback loop.
- Direct replacement for SwissTex (Rieter) rolls that include Dienes transmitters
- Frequency output
FEATURES & BENEFITS
Accurate – Within ± 0.1% (0.3°C) across entire sensing range.
Robust – Fully encapsulated electronics with generous clearance between rotor and stator.
Fully Compatible – A true drop-in replacement that fits existing shaft, works with existing wiring and process control systems.
Digital Circuitry – Maintains calibration and is immune to electrical noise and drift.
Intelligent – Protects heater if sensor or transmitter malfunctions.
Product Support – Backed by BEI’s reputation for the strongest customer support in the industry including a two-year warranty.
RT362 - SPECIFICATIONS
ROTOR
Number of sensors: 1 – 2
Sensor connection: Connector, Fischer PN: D 102 A021
Input sensor type: PT100 RTD (100 Ω at 0° C, α = .00385)
Sensor range: 0-300° C
Speed: 10,000 RPM
STATOR
Output connection: M3 SHCS to customer supplied ring lug wire terminals
Output signals: Frequency signal as current pulses on the power supply
(Dienes curve: 362.48 – 749.86 Hz)
Power Input: 11 – 18 VDC @ 30 mA nominal, 50 mA output pulse
GENERAL
Accuracy: ±0.10% FS over 25-50° C ambient temperature range for 50-250° C RTD readings
±0.17% FS over 25-85° C ambient temperature range for 0-300° C RTD readings
±0.20% FS over 25-85° C ambient temperature range for 0-300° C RTD readings
±0.33% FS over operating temperature range for 0-300° C RTD readings
Max Temp Coefficient: ±50ppm/° C over operating temperature range for 0-300° C RTD readings
Operating Temperature: 0-100° C
RECOMMENDED
RT351 SERIES
One-channel (RTD) system to replace Dienes-type transmitters. Includes speed and temperature signals. Multiple configurations available.
RT360 SERIES
A two-channel system with Dienes-compatible outputs for temperature control on J7/32 type Rieter machines.